Fluke 902FC True-RMS HVAC Digital Clamp Meter

SKU
4695814
$358.99
Ships direct from manufacturer?
Fluke 902 FC True-RMS HVAC Clamp Meter helps HVAC technicians work more efficiently on the work site. The Fluke 902 FC Clamp Meter, with Fluke Connect wireless connectivity, can help HVAC technicians improve productivity in the field. The rugged dual-rated CAT III 600 V, CAT IV 300 V meter equips you to perform many essential HVAC system measurements: microamps for testing pilot light sensors; resistance up to 60 kΩ; AC current and AC/DC voltage; capacitance; and contact temperature, all with just one tool. Plus its small form factor makes it easy to hang on to and navigate in tight work spaces. Part of the Fluke Connect wireless family. As part of the Fluke Connect family, the 902 FC can transmit measurements to a smartphone or tablet for later, detailed analysis. No need to write down the results. Trend and monitor measurements live on your phone screen, and upload those measurements to the cloud. Combine measurement data from multiple Fluke Connect test tools to create and share reports from the job site via email, and collaborate in real time with other colleagues with ShareLive video calls or email. The 902 FC can also decrease the frequency of wearing personal protective equipment (PPE) when working on high voltage/current panels. Simply turn off the panel. Verify that it is de-energized using standard safety procedures. Place the clamp and synch it to a smartphone. Close the panel, reenergize it, and take measurements from a safe distance.
WARNING: Proposition 65 Warning for California Residents View Details
More Information
Manufacturer Fluke
Condition New
Features
  • A wireless Fluke Connect-enabled clamp meter designed specifically for the needs of HVAC technicians
  • Offers 200 µA DC current measurements to measure flame rod
  • Extends resistance range to measure thermistors up to 60kΩ
  • Captures flue gas temperature
  • Measures start and run motor capacitors
  • Measures variable frequency drive performance
  • Ergonomic design fits in your hand and can be used while wearing personal protective equipment
  • Large, easy-to-read backlit display improves readings in low light settings
  • Connects to your smartphone via Fluke Connect so you can read measurements at a safer distance
  • Measures AC current to 600 A and AC and DC voltage to 600 V
  • Measures capacitance to 1000 µF and DC current to 200 µA
  • Measures temperature from -10 Deg C - 400 Deg C (14 Deg F - 752 Deg F)
  • Offers True-RMS voltage and current measurements to accurately measure non-linear signals
  • Measures resistance to 60 kΩ
  • Offers Min/Max recording to capture variations automatically
  • Runs on two AA alkaline batteries
Includes
  • TL75 Test Leads (1 Pair)
  • 80BK Integrated DMM Temperature Probe
  • 2 x AA Alkaline Batteries
  • Soft Carrying Case
  • User's Manual
PDFs
Battery Size AA
A AC (Via Jaw) Resolution0.1 A
A AC (Via Jaw) Accuracy2.0% ±5 Digit (45-65 Hz), 2.5% ±5 Digit (65-400 Hz)
A AC (Via Jaw) Range600.0 A
A AC (Via Jaw) Crest Factor (50Hz or 60Hz)2.5 MIN at 220 A, > 1.4 MIN at 600 A, 2% for CF>400 A
V AC Resolution0.1 V
V AC Accuracy1.5% ±5 Digits
V AC Range600.0 V
V DC Resolution0.1 V
V DC Accuracy1.5% ±5 Digits
V DC Range600.0 V
Ohms Resolution0.1/1/10
Ohms Accuracy1% ±5 Digits
Ohms Range600/6000/60.00 kΩ
Capacitance Resolution0.1/1 µF
Capacitance Accuracy1% ±4 Digits
Capacitance Range100.0/1000 µF
µA Resolution0.1 µA
µA Accuracy1% ±5 Digits
µA Range200 µA
Contact Temperature Resolution0.1 C/F
Contact Temperature Accuracy1% ±8 Digits
Contact Temperature Range-40 - 400 Deg C (-40 Deg F - 752 Deg F)
Continuity Beeper Volume75 dBA nom. 15 cm. From Case Front
Continuity Beeper On Threshold<=30 Ω
Maximum Voltage Between Any Terminal and Earth Ground1000 V
Temperature Operating-10 Deg C - +50 Deg C (14 Deg F - +122 Deg F)
Temperature Storage-40 Deg C - +60 Deg C (-40 Deg F - +140 Deg F)
Operating HumidityNon condensing (< 10 Deg C [50 Deg F]), ≤90 % RH (at 10 Deg C - 30 Deg C [50 Deg F - 86 Deg F]), ≤75 % RH (at 30 Deg C - 40 Deg C (86 Deg F - 104 Deg F)), ≤45 % RH (at 40 Deg C - 50 Deg C (104 Deg F - 122 Deg F))
Altitude Operating9.842'
Altitude Storage39.370'
Dimensions9.06"
Width3.30"
Height1.39"
Weight (Meter Only)0.923 lbs
SafetyIEC 61010-1, Pollution Degree 2, IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V, IEC 61010-2-033: CAT III 1000 V / CAT IV 600 V
IP RatingIEC 60529: IP30, Non-Operating
Radio Frequency CertificationFCC ID:T68-FBLE IC:6627A-FBLE
Electromagnetic Compatibility (EMC)International: IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A Korea (KCC): Class A Equipment (Industrial Broadcasting & Communication Equipment) USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103
Temperature Coefficients0.1 × Specified Accuracy for Each Degree C Above 28 Deg C or Below 18 Deg C